| Building Acoustics |
|
Analysers
|
Software
|
Sound Sources
|
Rotating Boom
|
|

|
Norsonic Nor-140
A robust and compact analyser for Building Acoustics
- Impulse or noise excitation reverberation time calculations
- Built in noise generator
- On screen index display of sound insulation in accordance with ISO 140/ 717.
- ISO 10052 Survey method for sound insulation testing implemented to give results on screen
|
|

Nor-140.pdf
|

|
Norsonic Nor-118
A robust and compact analyser for Building Acoustics
- Impulse or noise excitation reverberation time calculations
- Built in noise generator
- NEW option 11- On Board calculation of sound insulation (DnTw + Ctr etc) index in accordance with ISO 140/ 717.
- New ISO/DIS 10052 Survey method for sound insulation testing implemented to give results on screen
|
|

Nor-118 options.pdf
Nor-118 Building Acoustics.pdf
|
|
|
Norsonic Nor-1516 Wireless Building Acoustics System
The Norsonic Nor-1516 Wireless Building Acoustics system makes acoustic testing of partitions and room acoustics simple fast and fuss free while maintaining the accuracy of a twin microphone system.
- Twin Channel
- Quick set up and simple test procedure
- Full test certificate produced on site.
- Based around the Nor-118 Pocket
Analyser there is an advanced digital analyser for many other applications.
|
|

Nor-1516 system.pdf
Nor-1516 time savings.pdf
|
|

|
Norsonic Nor-121
- Twin channel
- Impulse or noise excitation reverberation time calculations
- Built in noise generator – Band filtered or broad band with built in graphic equalizer
- Insulation index calculated in the analyser and displayed on site
option. Revereberation time and level difference measurements can be made with low level output from speakers or where signal to noise is a problem.
|
|

Nor-121 Options.pdf
Nor-121AR Noise Nuisance Investigations
|
|
 
|
Nor-Build - Building Acoustics Software
Software for building acoustics to allow the 'drag and drop' of measured data from Norsonic analysers to instantly generate test reports.
- New Linear averaging of multiple speaker positions in accordance with approved document E of the building regulations
- Implements a wide range of National and International standards; e.g. ISO 140 / 717, ÖNORM, SIA
181, etc. Calculation of spectrum adaption terms C, Ctr and CI Direct calculation of R’w, R’J,w, DnTw, L’nw, L’nTw, etc.
Field and
laboratory measurement protocols supported
- Air and structure
borne insulation and absorption indices calculated
- Data editing and
selective averaging of the stored measurement data
- Graphical and
numerical display of the results
- Multiple display
of the results on the same diagram to aid comparison
- User friendly
presentation of results with direct print out of the standardised report
forms
- Export of the
entire project to Excel for user-specific formatting (inserting company logo,
changing the layout etc.)
|
|

Nor-Build.pdf
Control-Build.pdf
|
|

|
Norsonic Nor-250 Hemi Dodecahedron Loudspeaker
- Fulfils the directional characteristic required by the ISO 140-3 Standard when mounted on a
hard reflecting plane
- Delivers a
continuous sound power level of 120 dB over the frequency range 50 to 6300 Hz
- High efficiency speakers
6×170mm diameter (6.5")
- Dimensions 405 ×
150 mm. Weight 11.7 kg
- Input impedance
5.3ohm
|
|

Noise excitation.pdf
|
|

|
Norsonic Nor-270 & 270H Dodecahedron Loudspeakers
- Fulfils the directional characteristic required by the ISO 140-3
- Nor270H is high powered version
- Delivers a continuous sound power level of 120 dB (123dB Nor-270H) over the frequency range 50 to 6300 Hz
- High efficiency speakers 12×170mm diameter (6.5")
- Dimensions 450 diameter. Weight 11.7 kg, 20kg 270H
|
|

Noise excitation.pdf
|
|

|
Norsonic Nor-280 Power Amplifier
- Specially designed
for Building Acoustic measurements
- Lightweight and
rugged construction
- Self contained
noise generator
- 500 Wrms output
power
- Produces 120 dB sound
power level in the 50—5000 Hz frequency range when used with Norsonic
dodecahedron loudspeakers types Nor250 or Nor270. 123dB with Nor270H.
- Wireless remote
control of noise generator (optional)
- Equalization
network to optimise acoustic output from speaker
- Balanced signal
input for low noise.
|
|

Noise excitation.pdf
|
|

|
Norsonic Nor-277 Tapping Machine
- A lightweight compact
self contained sound source for making measurements to the latest versions of
the international standards. (ISO140 part VI, VII & VIII, ASTM E492 & ASTM E-1007 etc.)
- May be configured
for use on standard dimension staircase treads and fitted with rubber tipped
hammers for use on surfaces with a decorative finish
Wireless remote on
/ off control from handswitch or PC (optional) Powered from 230
volt AC main supply. Optional version operates from Li-Ion rechargeable battery.
Typically 1 hour operation time on internal battery
- Laser
sensor to measure the impact velocity to ensure that the energy imparted into the test floor is correct hence the effects of any friction or misalignment are immediately apparrent.
- Dimensions with feet retracted 165 x
230 x 295 mm. Weight 10 kg
|
|

Noise excitation.pdf
|
|

|
Norsonic Nor-265 Rotating Boom/ Turntable
- Building Acoustic measurement in accordance with ISO 140
- Reverberation Time measurements in accordance with ISO 354
- Sound Power measurements in accordance with ISO 3740 series
- Directional response measurements of loudspeakers and microphones
|
|

Nor-265.pdf
|